- RR
Thermal Metric Test Wall Construction and Installation
The Thermal Metric (TM) research project uses a novel hot box apparatus to investigate multiple factors that contribute to thermal performance… Read More
- RR
This report provides a summary of the Thermal Metric Project and results of Reference Wall testing. The Thermal Metric Project is a multi-year collaborative research project headed by Building… Read More
- RR
The Thermal Metric Hot Box Apparatus
For the purposes of the Thermal Metric (TM) research project a novel double-guarded hot box apparatus was designed and constructed (Figure 1). The apparatus is… Read More
- RR
The Thermal Metric (TM) project was initiated in 2007 to support good design and construction practices by improving the way thermal performance is measured. Ultimately, the project goal is to… Read More
- RR
Vancouver Test Hut Phases I-III Wall Assemblies
The Vancouver Test Hut is a 900 square foot field testing facility located in Coquitlam, BC, on the rooftop of the two story commercial office… Read More
- RR
Vancouver Test Hut Phase IV Wall Assemblies
The Vancouver Test Hut is a 900 square foot field testing facility located in Coquitlam, BC, on the rooftop of the two story commercial office building… Read More
- RR
The Vancouver Test Hut Facility
The Vancouver Test Hut is a 900 square foot field testing facility located in Coquitlam, BC, on the rooftop of the two story commercial office building occupied by… Read More
- RR
The Vancouver-area “leaky condo crisis” began to surface in the 1980s. An unusually large number of moisture-related problems, not only in condos but also in most building types, prompted extensive… Read More
- VID
Pagination
- Previous page
- Page 8
- Next page