Water Repellents for Brick Buildings

Water is weird…and I point this out in an admiring manner… Water by itself is weird…it is a “polar molecule think “tiny magnets”….but when it changes phase from a liquid to a solid or from a liquid to a vapor the weirdness goes to levels that mere mortals are left shaking their heads….or it leads them to drinking….apparently wine. More about the wine drinking later. Freeze-thaw damage, spalling and efflorescence are related in an amazing strange way. In freeze-thaw damage water changes from a liquid to a solid. In spalling and efflorescence water changes from a liquid to a vapor.

Ice Dams and R-Value of Snow

Ice dams happen when the outside temperature is below freezing, the roof deck temperature is above freezing, and there is snow on the roof. The warm roof deck causes the snow on top of the roof deck to melt, and the melt water runs down to the edge of the roof where the water freezes leading to a buildup of ice and a backup of water, hence the term “dam”.

Building Code v. Best Practices: Who's the Boss?

When I was a young punk kid in my 20’s and thought I was a builder the local building official would show up on my project site before I screwed up - he kept me out of trouble - he taught me enough building science that I became hooked. I was an engineer with a big time degree from a big time school but I did not know what I did not know. I respect building officials big time. That is why I am involved in the code process…I owe the code folks..it is my way of giving back...

Is 50% Relative Humidity The Right Amount?

The Harvard School of Public Health is recommending that we maintain interior relative humidity between 40 and 60 percent during the winter (https://www.hsph.harvard.edu/news/hsph-in-the-news/op-ed-humidity-can-ai...). I’m not arguing with the health science basis for this, just the building science basis for this: Relative humidities this high in houses[4] are going to be a killer in cold places where we have winter[5]. Yes, bad pun…

What Causes Truss Uplift?

Wood moves. Drywall does not move. Interesting problem. The more you attach drywall to wood, the more cracks you have. Easy, attach the drywall to less wood, and, in a way, that allows the wood to move. Nail pops happen because as wood dries, it shrinks. Nails do not shrink. Actually, nails do not pop. The wood shrinks away from the back face of the drywall as it dries. How about getting dry wood? Sure. Next question. Better to use shorter nails. Even better, use glue. With glue, as the wood shrinks, it pulls the drywall inwards with it.

Below-Grade Waterproofing for Deep Foundations

Peter Baker, P.Eng., is the President of Building Science Corporation. The Romans taught us about how to deal with foundations above the water table over 2,000 years ago. We are still figuring things out for foundations below the water table. Peter has been dealing with these things since before Wayne Gretzky was sent to the United States…which seems like it was about 2,000 years ago.

Multifamily Buildings and Summertime Humidity

Kohta Ueno is a Principal of Building Science Corporation and has an undergraduate degree in Material Science from the Massachusetts Institute of Technology and a Masters of Applied Science from the University of Waterloo. Over the past few years issues, including persistent summertime humidity, comfort complaints, sweating ductwork, and mold are increasing in recently constructed multifamily units. Problems are often due to a “perfect storm” of factors: from air conditioning sizing vs.

Technical Fixes—Another Government Program

Andy Padian is a recognized expert in buildings and building science despite receiving a BA from Syracuse University in Energy and Environmental Policy. He joins a list of notable Syracuse alumni including President Joe Biden and Jim Brown who was the greatest lacrosse player of all time. Andy is an independent consultant, founder and President of PadianNYC Consulting. His presentation deals with how “the next piece of technology” that is intended to solve building problems often results in a cascade of problems not fully known at the time of the technology introduction.