Video

Abbreviation
VID

Passive House and The Shifting Energy Landscape (Andrew Steingiser 2024)

Andrew is an architect with RDH in Boston and a graduate of the School of Architecture at Syracuse University. As Passive House is applied to multi-family buildings things get interesting...that is an understatement...there is more...wait till we look at schools...Phius and TEDI do not always get along...Andrew will help put things in focus...

Saving Affordable Homes (Julie Klump 2024)

Preservation of Affordable Housing (POAH) is a nonprofit developer, owner and operator of 20,000 affordable homes in multifamily buildings in twelve states and the District of Columbia. Julie is an architect and Vice President of Design and Building Performance for POAH. She has been involved in the retrofit and rehabilitation of thousands of existing homes and multifamily buildings and the design and construction of thousands of new affordable homes and multifamily buildings. Julie will discuss lessons learned and how to preserve affordability through high performance.

Passive-Regressive: Tales from the CUNY Building Performance Lab (Duncan Prahl 2024)

Duncan Prahl is an architect and the Director of Technical Services at the CUNY Building Performance Lab. He will share research projects and results conducted by the team at CUNY BPL...such as how well do those thousands of buildings in NYC actually perform and are those energy audits in NYC actually leading to any retrofits?

10-Year, 100-Year and 1,000 Year Buildings (Keith Simon 2024)

Keith Simon, FAIA is an architect, VP of Design Phase Services for Salas O'Brien, and adjunct faculty at the UT-Austin School of Architecture. He has some thoughts on how to design buildings to last for an extremely long period of time. As a Fellow of the AIA, he has some strong opinions on some of the priorities of architectural firms and architectural schools.

Wind-Driven Rain, Air Pressure, and Windows

Drainage is the key to life in general and pressure equalization—if it applies at all—is for joints and not for entire wall assemblies. Claddings need to be drained. Ventilated if you must, but first and foremost they need to be drained. Whereas joints in insulated glazing units, pre-manufactured windows both residential and commercial, joints in precast panels and connections between windows and wall assemblies can be pressure equalized but regardless they have to be drained.

Range hoods need Makeup Air

We can build a house so tight even Germans would be impressed. And then we forget about how to deal with a clothes dryer. Or we put in a kitchen range hood. Or we build a house with a fireplace. Or then we attach a garage. What are the odds that a house will have a clothes dryer, a kitchen range hood, a fireplace or an attached garage? I have news for you installing a cheap exhaust fan does not fix things. Installing an expensive one does not fix things either. Sucking does not work.

What Does "Build Tight and Ventilate Right" Mean?

Things have evolved considerably since the Eisenhower and Diefenbaker years. Hutcheon taught us about air flow that decade but it took more than a half century to get it right. We needed air control. We needed an air control layer – an air barrier. We started off with locating it on the inside, moved it to the middle, and finally ended up with it on the outside3. We started by combining it with a vapor barrier on the inside then we finished by combining it with a weather resistive barrier (WRB) and continuous insulation on the outside.

Joe sucks, and other 3-dimensional airflow realities (00:57)

Thirty years ago I said the moldiest buildings in the United States were air-conditioned hotels with vinyl wall coverings that operate under a negative air pressure….they literally “sucked”…. Not much has changed. For me to point that out is amazing. Maybe we need more attorneys…we are building them wrong faster than we can litigate them. That is not meant as a joke…some of the most effective “technology transfer” to practitioners in the construction industry is through the legal profession. Some of the physics is obvious…some not so much.