Ever wonder how we can build a 50 story glass tower that doesn’t leak, but we can’t seem to build a two-story house that doesn’t leak? The answer is a little bit of counter intuitive thinking.We have… Read More
- BSI
Here is a pop quiz for you folks that are bored of Jeopardy. California is desert. Florida is a swamp. We build concrete slab-on-grade in both places. Which place has more slab moisture problems? Yes… Read More
- BSI
Buildings today are hollow and multilayered with numerous air gaps or void spaces. Chases, shafts, soffits and drops abound. Everything is connected to everything else, typically unintentionally.… Read More
- BSI
The perfect wall is an environmental separator—it has to keep the outside out and the inside in. In order to do this the wall assembly has to control rain, air, vapor and heat. In the old days we… Read More
- BSD
- NEWS
The energy used in institutional, commercial, and industrial buildings in cold climates (zone 4 and above) is substantial. Most of this energy is used after construction is complete; hence, reducing… Read More
Cold
- BSD
Condensation within walls during cold weather is a common performance problem. Most such condensation is due to air leakage, not diffusion. Although air barrier and vapor control layers can reduce… Read More
Very Cold, Cold
- BSD
Putting metrics on building energy performance is a required step to make any progress on low-energy use and/or “green” buildings. However, there are many confusing and contradictory metrics… Read More
- BSD
The difference between site and source energy is a vital concept to understand when looking at the energy performance of buildings—failing to account for the difference will result in an apples-to-… Read More
- BSD
This digest offers a detailed explanation of the causes of carpet discoloration, particulate deposits on surfaces and "ghosting" of wood stud members on the interior gypsum board surfaces of exterior… Read More
- BSD
Unvented roof assemblies, such as conditioned attics and unvented cathedral ceilings, are becoming common in North American construction. These assemblies are created by eliminating ventilation… Read More
- BSD
Driving rain on building facades is on of the largest sources of moisture that impacts durability of enclosures. Several approaches to predicting driving rain on buildings have been developed over… Read More
- BSD
Stucco and EIFS are common cladding systems that appear similar from the exterior. These systems have very different attributes however. This Digest explains the reasons why face-sealed EIFS are… Read More
- BSD
The current building industry focus on durability is in part a reaction to the current perceived lack of it. Warranty claims and callbacks are increasingly leading to a rise in litigation and… Read More
- BSD
The American Foursquare, a Sears, Roebuck & Co. kit home, was a staple of small American towns between 1908 and 1940. More than 100,000 of them were built in America. Homes built prior to 1980… Read More
Cold
- BSD
Moisture is involved in most building problems. The most serious tend to be structural damage due to wood decay, unhealthy fungal growth, corrosion, freeze-thaw, and damage to moisture sensitive… Read More
- BSD
Ice dams are a common roof performance problem in buildings that experience snowfall and at least a month of below freezing temperatures. The combination of sufficient roof pitch, adequate insulation… Read More
Very Cold, Cold, Mixed-Humid
- BSD
Ice rinks and arenas are a common building type in many communities. The trend over the last 25 years has been to operate these arenas for greater periods of the year, often throughout the summer.… Read More
- BSD
Pitched roofs of either wood rafter and joist or truss construction are used in the construction of literally millions of homes and small commercial buildings each year. There are variations in these… Read More
- BSD
This digest reviews the moisture control principles that must be followed for a successful insulated retrofit of a solid load-bearing masonry wall. Two possible approaches to retrofitting such walls… Read More
Very Cold, Cold
- BSD
There has been a recent surge of interest in Ground Source Heat Pump (GSHP or “geothermal” or GeoExchange™) systems for residential projects. Outrageous claims and misunderstandings about how they… Read More
- BSD
This digest will begin with a brief description of the system and materials, review moisture problems in buildings, and summarize how moisture control should be dealt with in strawbale buildings.
- BSD
We learn our lessons from disaster. Hurricane Andrew taught us about wind. Hurricanes Charley, Frances and Jeanne taught us about rain. The Red River of the North Basin taught us about floods.… Read More
Mixed-Humid, Marine, Hot-Humid
- BSD
Are multifamily buildings one building or a bunch of individual buildings sharing the same structure? Should services and systems be shared or individual? The passions regarding these questions are… Read More
- BSD
Air flow in buildings is one of the major factors that governs the interaction of the building structure with the mechanical system, climate and occupants. If the air flow at any point within a… Read More
Hot-Humid, Hot-Dry/Mixed-Dry
- BSD
Water comes in four forms: solid, liquid, vapor and adsorbed. All four forms can cause grief to building owners, designers and contractors. When water causes building problems investigating and… Read More