- BA
Hygrothermal simulations such as WUFI are coming into increasingly common use among building science researchers and practitioners, architects and designers, and energy analysts. Such simulations… Read More
- BA
BSC worked directly with the David Weekley Homes (DWH) – Houston division to redesign three current floor plans in order to locate the heating, ventilation, and air conditioning (HVAC) system in … Read More
Hot-Humid
- BA
Between December of 2009 and December of 2012, participants in a deep energy retrofit (DER) pilot program sponsored by National Grid and conducted in Massachusetts and Rhode Island completed 42 DER… Read More
- BA
This report explains the moisture-related concerns for high R-value wall assemblies and discusses past Building America research work that informs this study. Hygrothermal simulations were prepared… Read More
- BA
In this project, the post-retrofit results for 13 existing homes from the DER Pilot program were analyzed. Ten of these homes are single-family homes; two are two-family homes, and one is a three-… Read More
- BA
The addition of insulation to the exterior of buildings is an effective means of increasing the thermal resistance of both wood framed walls as well as mass masonry wall assemblies. For thick layers… Read More
- BA
Exterior sheathing insulation is an effective strategy in increasing the overall R-value of wall assemblies; other benefits include decreasing the effects of thermal bridging and increasing the… Read More
- BA
Unvented roof strategies with open-cell and closed-cell spray polyurethane foam insulation sprayed to the underside of roof sheathing have been used since the mid-1990's to provide durable and… Read More
- BA
This project examines the implementation of an exterior insulation and over-clad strategy for brick masonry buildings in Chicago. The strategy was implemented at a free-standing two story two-family… Read More
Cold
- BA
This document covers a description of the need and applied solutions for supplemental dehumidification in warm-humid climates, especially for energy efficient homes where the sensible cooling load… Read More
Mixed-Humid
- BA
Airtight homes require rational and predictable ventilation. A key gap and area of ongoing research is to allow credit for better performing ventilation systems, such as supply and balanced… Read More
Hot-Humid
- BA
BA-1308: Moisture Control for Dense-Packed Roof Assemblies in Cold Climates: Final Measure Guideline
There is little consensus on the incidence of and physics behind moisture problems in dense-packed roof assemblies. Only a handful of field research projects have considered the moisture performance… Read More
Cold
- BA
Adding insulation to the interior side of masonry walls in cold climates may cause performance and durability problems. Four such concerns were studied in more detail in this work. Embedded wood… Read More
- BA
Transformations, Inc. is a residential development and building company that has partnered with Building Science Corporation to build new construction net-zero energy houses in Massachusetts under… Read More
Cold
- BA
Merrimack Valley Habitat for Humanity (MVHfH) has partnered with Building Science Corporation to provide high performance affordable housing for 10 families in the retrofit of an existing brick… Read More
- BA
This research provides simple, long term, and durable solutions when using tapes and flashing membranes in conjunction with the exterior face of rigid polymeric foam sheathing to create the drainage… Read More
- BA
Based on past experience in the Building America program, BSC has found that combinations of materials and approaches—in other words, systems—usually provide optimum performance. No single… Read More
- BA
In multifamily buildings, central (typically rooftop) ventilation systems often have poor overall performance, overventilating some portions of the building (resulting in excess energy use), while… Read More
- BA
Project Home Again is a development in New Orleans, Louisiana, created to provide new homes to victims of Hurricane Katrina. BSC acted as a consultant for the project, advocating design strategies… Read More
Hot-Humid
- BA
This guideline pertains to design and application guidance for combination space and tankless domestic hot water (DHW) heating systems (combination systems) used in residential buildings, based on… Read More
- BA
This project examines implementation of advanced retrofit measures in the context of a large-scale weatherization program and the archetypal Chicago, Illinois, brick bungalow. In response to the… Read More
Cold
- BA
The use of exterior insulation is an effective means to increase the overall thermal resistance of wall assemblies that also has other advantages of improved water management and often increased air… Read More
- BA
There is a significant push for energy performance upgrades to existing homes. An important target is often the windows. Old single-glazed windows have such low thermal resistance that their effect… Read More
- BA
Building Science Corporation (BSC) has been working with Byggmeister, a partner on the Building America (BA) team, on retrofit projects under the BA program. Byggmeister is a local design-build firm… Read More
Cold
- BA
Through discussion of five case studies (test homes), this project evaluates strategies to elevate the performance of existing homes to a level commensurate with best-in-class implementation of high… Read More
Cold
- BA
Historically, weatherization programs have required that cellulose insulation materials be dense-packed to a minimum installed density of 3.5 pcf. This density limit was, in part, required to realize… Read More
- BA
Basements can account for up to one quarter of the typical energy consumption in a house. Therefore, insulating foundations is a critical measure for achieving high performance buildings. However,… Read More
- BA
Building Science Corporation seeks to further the energy efficiency market for cold climate, New England area retrofits by supporting projects based on solid building science fundamentals and… Read More
Cold
- BA
This project examines a large scale renovation project within a 500 unit, 1960’s era subsidized urban housing community. The development comprises low-rise and mid-rise structures both of which… Read More
Cold
- BA
Load-bearing masonry buildings are a significant portion of the existing building stock. Given the Building America goals of reducing home energy use by 30%-50% (compared to 2009 energy codes for new… Read More
- BA
Successfully executing strategies to control bulk water for foundations is critical for building durability, indoor air quality, and creating acceptable conditions and/or living spaces within the… Read More
- BA
The following report is an excerpt from the 2010 Building Science Corporation Industry Team Building America Annual Report. The main focus for this research project is the integration of a… Read More
- BA
The following report is an excerpt from the 2010 Building Science Corporation Industry Team Building America Annual Report. The main focus for this research project is on the AAON heat pump system… Read More
Hot-Humid
- BA
The following report is an excerpt from the 2010 Building Science Corporation Industry Team Building America Annual Report. The goal of this research is to find optimally designed, cost effective… Read More
- BA
The following report is an excerpt from the 2010 Building Science Corporation Industry Team Building America Annual Report. Many concerns, including the rising cost of energy, climate change concerns… Read More
- BA
The following report is an excerpt from the 2010 Building Science Corporation Industry Team Building America Annual Report. This report investigates the implementation of advanced framing in both… Read More
- BA
The following report is an excerpt from the 2010 Building Science Corporation Industry Team Building America Annual Report. Many concerns, including the rising cost of energy, climate change concerns… Read More
- BA
This paper describes a hygrothermal modeling study, including all of the US climate zones, a range of interior humidity levels and numerous arrangements and types of insulation. The results showed… Read More
- BA
Building America is a program of the U.S. Department of Energy, in which teams of architects, engineers, builders, equipment manufacturers, and others collaborate in a systems engineering approach to… Read More
- BA
The following report is an excerpt from the 2009 Building Science Corporation Industry Team Building America Annual Report. BSC has been active for many years in working to help identify and address… Read More
- BA
The following reports are excerpts from the 2009 Building Science Corporation Industry Team Building America Annual Report. These prototype house project summaries include whole-house performance and… Read More
- BA
The following reports are excerpts from the 2009 Building Science Corporation Industry Team Building America Annual Report. These community scale evaluations include whole-house performance and… Read More
- BA
The following reports are excerpts from the 2009 Building Science Corporation Industry Team Building America Annual Report. These summaries are for the following advanced system research projects: … Read More
- BA
Many concerns, including the rising cost of energy, climate change concerns, and demands for increased comfort, have lead to the desire for increased insulation levels in many new and existing… Read More
- BA
The goal of this project was to create a home with a high R-value enclosure, a right-sized mechanical system, energy efficient lighting, appliances, windows and doors, and also have the possibility… Read More
Cold
- BA
The combination of tankless hot water heating and solar hot water heating creates some challenges that we have been researching with our builder partner, Coastal Habitats/Coastal Green Building… Read More
- BA
Following the almost complete destruction of Greensburg, Kansas by a tornado in May, 2007, Building Science Corporation (BSC) was contracted to provide example house plans, support for the… Read More
- BA
Following the almost complete destruction of Greensburg, Kansas by a tornado in May, 2007, Building Science Corporation (BSC) was contracted to provide example house plans, support for the… Read More
- BA
This paper discusses Building America whole house systems research within the broad effort to reduce or eliminate the environmental impact of building and provides specific recommendations for future… Read More
- BA
Given what happened in New Orleans during hurricane Katrina, changes in the way we build are needed. Looking to key sustainability concepts of durability and energy efficiency, new flood resistant… Read More
Hot-Humid