- RR
This document summarizes the theory behind thermal insulation and building system heat flow control metrics and presents a literature review of selected research into this area. As the building… Read More
- RR
Concentrations of 54 volatile organic compounds (VOCs) and ventilation rates were measured in four new manufactured houses over 2-to-9.5 months following installation and in seven new site-built… Read More
Mixed-Humid, Hot-Humid
- RR
This paper reviews current ventilation codes and standards for residential buildings in Europe and North America. It also examines the literature related to these standards such as occupant surveys… Read More
- RR
The purpose of this research program was to determine the impact resistance performance of advanced framed wall systems with insulating sheathing as the primary sheathing from wind blown debris. With… Read More
- RR
A performance review of residential assemblies in the central Florida (Orlando) area during the three hurricanes in August and September 2004. The specific focus of the review is on the water… Read More
Hot-Humid
- RR
Two seemingly innocuous requirements for building enclosure assemblies bedevil builders and designers almost endlessly: keep water vapor out, let the water vapor out if it gets in. It gets… Read More
- RR
Just about everyone in the building industry can be guilty of using building terms loosely, and a prime example is with attics, roof assemblies. You can vent single components, you can vent… Read More
- RR
Good design and practice involve controlling the wetting of building assemblies from both the exterior and interior and different climates require different approaches. Ideally, building assemblies… Read More
- RR
Exposure to sunlight (ultraviolet radiation) and moisture are the major factors affecting the durability of paint coatings and the durability of the substrate. Ultraviolet radiation, moisture and… Read More
- RR
Construction practices have improved and the HVAC systems need to improve with them. The deKieffer Bypass relieves air pressure in rooms without compromising sound or light transmission.
- RR
This report presents a 3D window installation sequence with detailed step-by-step instructions on how to effectively install a window using building paper as the drainage plane. These details were… Read More
- RR
Exterior insulation and finishing systems (EIFS) are inherently defective and unfit of use as an exterior cladding system where moisture sensitive components are used without a provision for drainage… Read More
Hot-Dry/Mixed-Dry
- RR
Roofs can be designed and constructed to be either vented or unvented in any hygrothermal zone. Air barrier systems are typically the most common approach, however, air pressure control approaches… Read More
- RR
Air barriers are systems of materials used to control airflow in building enclosures. They typically completely enclose the air within a building. The physical properties which distinguish air… Read More
- RR
A concise explanation of how a high performance HVAC system works in a high performance home. How can I be saving energy, money, and wear and tear on my equipment if it seems as though my system is… Read More
- RR
When constructing unvented roofs with asphalt shingles in hot humid climates, a vapor barrier must be installed between the asphalt shingles and the roof deck. Asphalt shingles store water from dew (… Read More
- RR
The simplest, most effective, and most economical way to introduce fresh air in homes with central forced air systems is to use the central fan to pull in and distribute a controlled amount of… Read More
- RR
"Buildings leak water and air, which is normal and unavoidable. Therefore, designers should not fixate on preventing leakage, i.e. making buildings “airtight.” Because even if all cracks were sealed… Read More
- RR
This article was written to tie together and summarize the various papers on unvented conditioned cathedralized attics found on our website. We realize that there is a wealth of information, and much… Read More
- RR
This article briefly repeats some of the information in the other mold articles but also includes information on how to prevent mold in residential structures. Mold requires water. No water, no mold… Read More
- RR
The purpose of this document is to assist builders with the decisions regarding what to do and how to do it when mold is found in specific locations. This article provides both general guidelines for… Read More
- RR
Mold testing procedures were not developed to determine whether a home is “safe” or “healthy” or “clean." Although this article is titled "Mold Testing" it actually tells you why testing for mold is… Read More
- RR
Too much mold can affect the health of you and your family. In addition, mold can damage or destroy building materials such as wood or gypsum board in our homes. This article answers your questions… Read More
- RR
Builders for many years have put mechanical equipment and ducts in non-living spaces such as crawlspaces and attics primarily to save valuable floor space. Be that as it may (there are lots of good… Read More
- RR
What relative humidity should I have in my home? Seems like a simple enough question. However, the answer can sometimes be difficult to understand.